§5.0 SYSTEM FLUSH AND PERFORMANCE VERIFICATION

Although MN-800-TF systems are fully tested at the factory prior to shipping, it is recommended to flush and verify your system's performance on-site.

§5.1 SYSTEM FLUSH AND OPERATION

New membranes have a preservative on them that needs to be flushed before use.

Open the fast flush valve and all usage outlets to allow product to run to drain.

Fully open the concentrate recirculation valve by turning the knob counterclockwise.

Insure the valve on the By-Pass Panel is in the NORMAL position.

Turn on the water supply to the unit and check for leaks up to the solenoid valve (just after the feed water filter outlet).

Plug the system into an electrical outlet. CAUTION! THE SYSTEM WILL START

IMMEDIATELY.

After the system has run for a few minutes to clear any air, turn the concentrate recirculation valve clockwise to close then open a quarter turn. CAUTION! BE SURE THE FLUSH VALVE IS OPEN.

Allow the system to flush for one hour with all water discharged to drain. Open the concentrate recirculation valve then close the flush valve. Gradually turn the concentrate recirculation valve clockwise until the system pressure gauge reads 180 psi (12.4 bar).

Check for leaks and check the system pressure gauge. It is likely that the system pressure will drift from 180 psi (12.4 bar) during this first high pressure run time, if it does turn the concentrate recirculation valve clockwise to increase pressure or counterclockwise to decrease pressure. CAUTION: DO NOT LET SYSTEM PRESSURE RISE ABOVE 200 PSI (14 BAR) AS DAMAGE CAN OCCUR.

Insure the ball valve on the tank outlet is open. Allow the system to make product for at least 5 minutes then check the TDS of the product by pressing the red button on the Monitor in the By-Pass Panel, the Green LED should light.

Close all food service machine valves. The unit will now make product water, which will go to the pressurized storage tank. Observe a gradual rise in the product gauge on the RO unit or on the BY-Pass Panel. Allow the tank pressure to rise.

As the product pressure increases check for leaks in all product plumbing. When the product tank pressure reaches about 60 psi the RO should turn off, this could take one hour or more. Open a food service valve and observe a gradual drop in the tank pressure from 60 psi. When the pressure drops to about 40 psi the RO should come back. Close the food service valve.

12

Page 12
Image 12
Nimbus Water Systems MN-800-TF manual §5.0 System Flush and Performance Verification, Immediately

MN-800-TF specifications

The Nimbus Water Systems MN-800-TF is an innovative water filtration system designed to provide homes with clean, safe, and great-tasting water. Emerging as a leading solution in the water purification market, the MN-800-TF stands out due to its advanced features and cutting-edge technologies that cater to diverse filtration needs.

One of the main features of the MN-800-TF is its multi-stage filtration process, which includes a combination of sediment filters, activated carbon, and reverse osmosis membranes. This multi-tier approach ensures that a wide range of impurities such as chlorine, heavy metals, sediments, and even microorganisms are effectively removed from the water. This results in not only improved taste but also enhanced safety for household consumption.

The system utilizes advanced filtration technologies, including a high-capacity reverse osmosis membrane that boasts an impressive rejection rate for dissolved solids. This technology ensures that the water retains essential minerals while eliminating harmful contaminants. The activated carbon filters are designed to reduce chlorine levels and volatile organic compounds, resulting in water that is pure and refreshing.

In terms of user convenience, the MN-800-TF is equipped with an easy-to-read digital display that provides real-time information regarding filter status and water quality. The system also features a simple, intuitive setup process and space-saving design, making it suitable for both small and large homes. The compact design allows for installation under sinks or in utility rooms, optimizing space without compromising efficiency.

Another notable characteristic of the MN-800-TF is its sustainable approach. The system is designed to produce minimal wastewater during the filtration process, which is a critical consideration given the rising concern over water conservation. Moreover, by using a reusable filter system, users can reduce plastic waste generated from traditional bottled water usage.

The Nimbus Water Systems MN-800-TF is also backed by robust customer support and a warranty, ensuring peace of mind for users. Overall, this water filtration system integrates advanced technology and user-friendly features, making it an optimal choice for anyone looking to enhance their home’s water quality. With its combination of efficiency, sustainability, and reliability, the MN-800-TF truly embodies the future of home water purification.