Nordyne E3 user service SYSTEM CHECKOUT Checking Installation, Blower Performance, Clearances

Models: E3

1 32
Download 32 pages 24.59 Kb
Page 21
Image 21
SYSTEM CHECKOUT

SYSTEM CHECKOUT

Checking Installation

1.Refer to appropriate wiring diagram and recheck all wiring connections. Ensure that all connections are tight.

2.Check blower motor and relay box con- nectors for proper connection.

3.Reinstall control box cover(s).

4.Switch circuit breaker(s) to “ON” position.

5.Set furnace blower selector switch (see Figure 16) to “AUTO” (EH Units only).

6.Replace outer furnace door.

7.Check all duct connections and tape for air leakage.

Standard E3EH Blower with Filter, @ 0.3" ESP

Pin No.

Speed

 

CFM

 

 

 

 

#1

Low

 

840

 

 

 

 

#2

High

 

1160

 

 

 

 

4-Ton Blower with Coil and

 

Coil and Filters, @ 0.3" ESP

 

Pin No.

Speed

 

CFM

 

 

 

 

#1

Low

 

880

 

 

 

 

#2

Med.-Low

 

1170

 

 

 

 

#3

Med.-High

 

1310

 

 

 

 

#4

High

 

1460

 

 

 

 

5-Ton Blower, with Coil and

 

Coil Filters, @ 0.3" ESP

 

 

 

 

Pin No.

Speed

 

CFM

 

 

 

 

#1

Low

 

990

 

 

 

 

#2

Med.-Low

 

1320

 

 

 

 

#3

Med.-High

 

1620

 

 

 

 

#4

High

 

1790

 

 

 

 

Multi-Speed, X13, Blower, with

 

Coil and Filters, @ 0.3" ESP

 

 

 

 

Pin No.

Speed

 

CFM

 

 

 

 

#1

Low

 

880

 

 

 

 

#2

Med.-Low

 

1000

 

 

 

 

#3

Med

 

1170

 

 

 

 

#4

Med.-High

 

1260

 

 

 

 

#5

High

 

1460

 

 

 

 

Table 6. Blower Performance

Furnace

 

 

Thermostat

Model

 

Anticipator Setting

010, 012

 

0.2

 

 

 

 

 

 

 

015, 017, 020, 023

 

0.4

 

 

 

 

 

 

Table 7. Anticipator Settings

 

 

 

 

 

ALL MODELS

 

CLOSET

ALCOVE

Front **

 

6"

 

18"

Back

 

0"

 

0"

Sides

 

0" *

 

0" *

Top

 

0"

 

0"

Top and Sides of Duct

 

0"

 

0"

Bottom of Duct

 

0"

 

0"

**Service Clearance

*For upfl ow application using upfl ow stand, 1” minimum per side.

Table 8. Clearances

21

Page 21
Image 21
Nordyne E3 user service SYSTEM CHECKOUT Checking Installation, Blower Performance, Clearances