SYSTEM CHECKOUT
Checking Installation
1.Refer to appropriate wiring diagram and recheck all wiring connections. Ensure that all connections are tight.
2.Check blower motor and relay box con- nectors for proper connection.
3.Reinstall control box cover(s).
4.Switch circuit breaker(s) to “ON” position.
5.Set furnace blower selector switch (see Figure 16) to “AUTO” (EH Units only).
6.Replace outer furnace door.
7.Check all duct connections and tape for air leakage.
Standard E3EH Blower with Filter, @ 0.3" ESP
Pin No. | Speed |
| CFM |
|
|
|
|
#1 | Low |
| 840 |
|
|
|
|
#2 | High |
| 1160 |
|
|
|
|
| |||
Coil and Filters, @ 0.3" ESP |
| ||
Pin No. | Speed |
| CFM |
|
|
|
|
#1 | Low |
| 880 |
|
|
|
|
#2 |
| 1170 | |
|
|
|
|
#3 |
| 1310 | |
|
|
|
|
#4 | High |
| 1460 |
|
|
|
|
| |||
Coil Filters, @ 0.3" ESP |
| ||
|
|
| |
Pin No. | Speed |
| CFM |
|
|
|
|
#1 | Low |
| 990 |
|
|
|
|
#2 |
| 1320 | |
|
|
|
|
#3 |
| 1620 | |
|
|
|
|
#4 | High |
| 1790 |
|
|
|
|
| |||
Coil and Filters, @ 0.3" ESP |
| ||
|
|
| |
Pin No. | Speed |
| CFM |
|
|
|
|
#1 | Low |
| 880 |
|
|
|
|
#2 |
| 1000 | |
|
|
|
|
#3 | Med |
| 1170 |
|
|
|
|
#4 |
| 1260 | |
|
|
|
|
#5 | High |
| 1460 |
|
|
|
|
Table 6. Blower Performance
Furnace |
|
| Thermostat | ||
Model |
| Anticipator Setting | |||
010, 012 |
| 0.2 |
| ||
|
|
|
|
|
|
015, 017, 020, 023 |
| 0.4 |
| ||
|
|
|
|
| |
Table 7. Anticipator Settings |
| ||||
|
|
|
| ||
ALL MODELS |
| CLOSET | ALCOVE | ||
Front ** |
| 6" |
| 18" | |
Back |
| 0" |
| 0" | |
Sides |
| 0" * |
| 0" * | |
Top |
| 0" |
| 0" | |
Top and Sides of Duct |
| 0" |
| 0" | |
Bottom of Duct |
| 0" |
| 0" |
**Service Clearance
*For upfl ow application using upfl ow stand, 1” minimum per side.
Table 8. Clearances
21