Nordyne E3 Typical Installation Of Upflow Systems, Holes, Closet, Door, Special 1 Clearance

Models: E3

1 32
Download 32 pages 24.59 Kb
Page 15
Image 15
Figure 13. Typical Alcove Installation

Wall

 

 

Return

Panel

 

 

Air

 

 

 

Grille

Coil Air

 

 

 

Filters

 

 

27"

 

 

 

 

 

(686 mm)

 

 

 

56"

 

 

 

(1423 mm)

A/C or H/P

 

 

 

Coil

 

 

 

 

 

 

29"

24 3/4"

 

( 737 mm)

 

 

 

(629 mm)

Furnace

 

 

 

 

 

 

Front

 

 

 

 

 

18"

 

20"

 

Nearest

 

 

Wall or

Floor

(508 mm)

Partition

 

 

Figure 13. Typical Alcove Installation

2.Remove refrigerant line knockouts in fur- nace only when installing indoor coil of an air conditioner or heat pump system, or for hook-up of a VentilAire accessory when the furnace is used in the upfl ow position. Refer to instructions supplied with accessory equipment.

3.Remove unit front door and slide back until bottom slots in rear of unit engage with both tabs of optional rear mounting plate, OR...

If mounting plate is not used, an equivalent method of securing the rear of the unit may be used as long as it prevents displacement during transport if used in a manufactured home.

Holes (4)

Wall-Mount

Return Air Grille

Closet

Door

Figure 14. Typical Closet Installation

Provide min. 235 sq. in. (1516 cm ) open free area in front or side wall or in top of closet door

0" Side

 

 

Clearance

 

 

to Furnace

 

 

Cabinet

(152

6"

 

 

mm)

 

 

CLOSET DOOR

Standard Closet Installation

NOTE: The furnace does not need to be hard up against the rear mounting plate.The tabs will engage into the slots and allow approximately 1/2” of furnace adjustment front to back and right to left.

4.Secure front of unit with one or more fas- teners at mounting hole(s) provided or at tie-down tab (see Figure 16).

5.See Electrical System Installation to com- plete furnace installation.

0" Side Holes (4)Closet Clearance to Furnace Cabinet

Provide min. 250 sq. in. (1613 cm2 ) open free area in front or side wall Door or in top of closet door

(25

1"

mm)

 

TYPICAL INSTALLATION OF UPFLOW SYSTEMS

The following steps describe installation instruc- tions for an overhead supply duct system with a return air system that can be either over the fl oor (unducted) or through the fl oor (ducted).

CLOSET DOOR

Special 1" Clearance

Figure 15. Closet Installation

15

Page 15
Image 15
Nordyne E3 Typical Installation Of Upflow Systems, Holes, Closet, Door, Typical Alcove Installation, Special 1 Clearance