Secure Duct Connector and Mounting
Plate with 2 Flat-Head Screws or Nails
Mounting Plate
Duct
Connector
14" Supply Connection
Figure 9. Platinum Duct Connector
Method D
1.Score and cut top of metal duct as indicated in Figure 12, Step 1 or Step 2. If using Step 1, also cut out metal from the shaded area “A”.
2.Fold the duct fl ap “B” up (see Figure 12, Step 3).
3.At the
4.At area “B”, bend the duct connector tabs up and back over, around the duct connector (see Figure 12, step 3).
5.Fold/form the duct fl ap against the side of the duct connector and attach as shown (see Figure 12, Step 4). Use at least three staples on each duct fl ap OR... if a 2X block/joist is not provided, use at least two sheet metal fasteners on each duct fl ap.
6.Seal the duct fl ap edges with an approved tape or compound for a
Method E
1.Apply a bead of caulking, mastic, or other approved sealant around bottom side of 1/2” fl ange and restrictor plate, when ap- plicable.
TABS | TABS |
DUCT | DUCT |
1. INSERT DUCT CONNECTOR | 2. BEND BOTTOM TABS OVER |
INTO DUCT | AND ONTO THE UNDER- |
| NEATH DUCT SURFACE |
Figure 10. Duct Connector Installation B
13