94 Chapter 7 Setting media bay module DIP switches

N0008587 01

Table 15 shows the switch settings for each DS30 bus, and the resulting line assignments.

BRI switch settings

You can install a maximum of three BRI modules per DS30 bus on the offsets indicated below.

Table 16 shows the switch settings for each DS30 bus, and the resulting line assignments.

Table 15 DTM switch settings (E1 and UK PRI)

Select
DS30 bus
#
Enter these switch settings To
assign
these
lines
Select
DS30
bus #
Enter these switch settings To
assign
these
lines
123456 1 2 3 456
02 on on on on on on 211-240 05 on on on on 121-150
off off
03 on on on on on 181-210 06 on on on on on 91-120
off off
04 on on on on on 151-180 071on on on on 61-90
off off off
1If your system is configured with a 3/5 DS30 split, DS30 07 is not available.

Table 16 BRIM S/T switch settings

Select
DS30
bus #
Select
offset
Enter these switch
settings
To
assign
these
lines
Select
DS30
bus #
Select
offset
Enter these switch
settings To assign
these
lines
123456 12 3 456
02
0on on on on on on 211-218
05
0on on on on 121-128
off off
1on on on on on 219-226 1on on on 129-136
off off off off
2on on on on on 22 7-234 2on on on 137-144
off off off off
03
0on on on on on 181-188
06
0on on on on on 91-98
off off
1on on on on 189-196 1on on on on 99-106
off off off off
2on on on on 197-204 2on on on on 107-114
off off off off
04
0on on on on on 151-158
071
0on on on on 61-68
off off off
1on on on on 159-166 1on on on 69-76
off off off off off
2on on on on 167-174 2on on on 77-84
off off off off off
1 If your system is configured with a 3/5 DS30 split, DS30 07 is not available.