138 Chapter 10 Wiring the modules
N0008587 01
Wiring media bay modules to internal connections
After you have the trunk modules wired, you can install the wiring to the station modules. These
are the modules which connect to the internal telephone sets.
All station module wiring uses 25-pair cable with a female amphenol connector at the media bay
module end.
Follow these steps to connect the wiring for the DSM 16, DSM 32, ASM 8, GASM8, or 4X16
modules:
1Wire 16 wire pairs from the amphenol connector to the local connecting blocks so they
connect to the 16 station sets you want connected to this module.
Use Table 34 and Figure 57 on page 139.
For an overview of BIX wiring conventions, refer to the Business Communications Manager
BIX Box Wiring Guide.
2Install the telephones and peripheral equipment wiring (if new system):
aAttach the cables for the telephones to the connecting blocks.
bInstall the telephones. Each telephone comes with hardware installation instructions.
Refer also to Chapter 13, “Installing optional telephony equipment,” on page 157.
cTo connect analog equipment to a digit line, refer to Chapter 12, “Installing Analog
Terminal Adapters,” on page 149.
Note: DSM 32 modules require two 25-pair cables.
Note: Use 16 wire pairs from each connector for the DSM 32.
Note: If you are connecting an DSM 16, 4X16, or DSM 32, use Table 34 on page 139.
If you are connecting an ASM 8 or GASM8, use the Table 35 on page 140.
Note: You can configure most types of telephones before they are installed. Refer to the
Programming Operations Guide for specific instructions about telephone settings and
using the New Users Wizard to set up telephones.