168 Chapter 15 Preparing hardware for maintenance or upgrades
N0008587 01
Shutting down the system software
The Business Communications Manager system requires a controlled shutdown to guarantee the
integrity of the file system. Sometimes this may not be possible, for instance if a hard drive fails.
However, as long as you have access to the Unified Manager, perform the following procedures
before removing power from the system:
1Start a web browser on a computer with a LAN connection to the Business Communications
Manager system.
2Enter the IP address of the Business Communications Manager system and the port number
for Business Communications Manager Unified Manager (:6800).
For example: http://10.10.10.1:6800.
3Click the Configure button.
4Type your user name in the Login box.
5Type your password in the Password box.
6Choose System.
7Click the Logoff menu and then click Shutdown.
8Click the Yes button.
9Wait until the Status changes to Complete! It is safe to turn off the system.
10 Click the Done button.
11 Quit the web browser.