Once it is SET by one of these commands:

a. It will remain set until power is cycled on the unit.

b. Non-address DIP switch changes on a connected KEYPAD connected to this zone will be ignored.

If override state is "0", this response is also issued whenever non-address KEYPAD DIP switches are changed.

*********************************************************************************

COMMAND:

*ZxxON<CR> – Turn zone xx ON.

RESPONSE:

Same response as for *ZxxCONSR<CR>

*********************************************************************************

COMMAND:

*ZxxOFF<CR> – Turn zone xx OFF.

RESPONSE:

Same response as for *ZxxCONSR<CR>

*********************************************************************************

COMMAND: *ALLOFF<CR> – Turn ALL zones OFF.

RESPONSE: #ALLOFF<CR>

This RESPONSE is also issued when ALL OFF is pressed on any KEYPAD.

*********************************************************************************

COMMAND: *ALLV+<CR> – Ramp ALL zones UP at a 10 dB/second rate in 1 dB steps.

RESPONSE: #ALLV+<CR>

The ramp action will be cancelled when all zones reach MAXIMUM volume, or when an *ALLHLD<CR> Command is received. Note that to stop the ramp with this command before maximum volume, one reference zone must be periodically polled with a *ZxxCONSR<CR> Command to determine when the desired volume point has been reached. Note that ramps in different zones may start at different levels and will all ramp at the same rate.

*********************************************************************************

COMMAND: *ALLV-<CR>– Ramp ALL zones DOWN at a 10 dB/second rate in 1 dB steps.

RESPONSE: #ALLV-<CR>

The ramp action will be cancelled when all zones reach MINIMUM (OFF) volume, or when an *ALLHLD<CR> Command is received. Note that to stop the ramp with this command before the minimum volume, one reference zone must be periodically polled with a *ZxxCONSR<CR> Command to determine when the desired volume point has been reached. Note that ramps in different zones may start at different levels and will all ramp at the same rate.

*********************************************************************************

COMMAND: *ALLHLD<CR> – Stops ramp action initiated by *ALLV+<CR> Or *ALLV-<CR>

RESPONSE: #ALLHLD-<CR>

This results in a HOLD of the level at time of command receipt.

*********************************************************************************

COMMAND:

*ALLMON<CR> – ALL MUTE ON.

RESPONSE:

# ALLMON<CR>

*********************************************************************************

COMMAND: *ALLMOFF<CR> – ALL MUTE OFF.

RESPONSE: #ALLMOFF<CR>

********************************************************************************

COMMAND:

*ZxxSRCp<CR> – Switch zone xx to SOURCE p ( 1 to 6).

RESPONSE:

Same response as for *ZxxCONSR<CR>

*********************************************************************************

28

Page 28
Image 28
Nuvo NV-E6DXS, NV-E6DMS owner manual # Allmoncr