COMMAND:

*ZxxVOLyy<CR> – Set volume of zone xx to level yy below max in dB from –0 to –78 dB

 

(include lead 0 for all single-digit values).

RESPONSE:

Same response as for *ZxxCONSR<CR>

*********************************************************************************

COMMAND:

*ZxxVOL+<CR> – STARTS zone xx volume ramp UP at the rate of +10 dB per second in +1 dB steps.

 

(This is the same as holding VOLUME UP key on a KEYPAD for 1 second).

RESPONSE:

Same response as for *ZxxCONSR<CR>, updated 10 times per second.

*********************************************************************************

COMMAND:

*ZxxVOL-<CR>– STARTS zone xx volume ramp DOWN at the rate of -10 dB per second in -1 dB steps.

 

(This is the same as holding VOLUME UP key on a KEYPAD for 1 second).

RESPONSE:

Same response as for *ZxxCONSR<CR>, updated 10 times per second.

*********************************************************************************

COMMAND: *ZxxVHLD<CR> – STOPS zone xx volume ramp initiated by *ZxxVOL+<CR> or *ZxxVOL-<CR>commands. This results in a HOLD of the level at time of command receipt. RESPONSE: #ZxxVHLD<CR>

*********************************************************************************

COMMAND:

*ZxxMTON<CR> – zone xx MUTE ON (mutes currently connected source)

RESPONSE:

Same response as for *ZxxCONSR<CR>

*********************************************************************************

COMMAND:

*ZxxMTOFF<CR> – zone xx MUTE OFF (returns zone output to currently connected source at previous volume setting).

RESPONSE:

Same response as for *ZxxCONSR<CR>

*********************************************************************************

COMMAND:

*ZxxBASSyyy<CR> – zone xx BASS EQ with yyy = EQ level, dB, –12 to +0 (flat) to +12 in 2 dB increments.

 

USE LEAD "0" IN TENS PLACE FOR VALUE LESS THAN 10.

RESPONSE:

Same response as for *ZxxSETSR<CR>

NOTE: sending this command to the E6D will set override (lock out KEYPAD non-address DIP switches) for this zone until power is cycled.

*********************************************************************************

COMMAND:

*ZxxTREByyy<CR> – zone xx TREBLE EQ with yyy = EQ level, dB, –12 to +0 (flat) to +12 in 2 dB increments.

 

USE LEAD "0" IN TENS PLACE FOR VALUE LESS THAN 10.

RESPONSE:

Same response as for *ZxxSETSR<CR>

NOTE: sending this command to the E6D will set override (lock out KEYPAD non-address DIP switches) for this zone until power is cycled.

*********************************************************************************

COMMAND:

*ZxxGRPON<CR> – zone xx SOURCE GROUP ON.

RESPONSE:

Same response as for *ZxxSETSR<CR>

NOTE: sending this command to the E6D will set override (lock out KEYPAD non-address DIP switches) for this zone until power is cycled.

*********************************************************************************

COMMAND:

*ZxxGRPON<CR> – zone xx SOURCE GROUP ON.

RESPONSE:

Same response as for *ZxxSETSR<CR>

NOTE: sending this command to the E6D will set override (lock out KEYPAD non-address DIP switches) for this zone until power is cycled.

*********************************************************************************

COMMAND:

*ZxxGRPOFF<CR> – zone xx SOURCE GROUP OFF.

RESPONSE:

Same response as for *ZxxSETSR<CR>

NOTE: sending this command to the E6D will set override (lock out KEYPAD non-address DIP switches) for this zone until power is cycled.

29

Page 29
Image 29
Nuvo NV-E6DMS, NV-E6DXS owner manual USE Lead 0 in Tens Place for Value Less than