RESPONSE: #ZxxLKON<CR>

*********************************************************************************

COMMAND:

*ZxxVRSTON<CR> – zone xx VOLUME RESET ON.

RESPONSE:

Same response as for *ZxxSETSR<CR>

NOTE: sending this command to the E6D will set override (lock out KEYPAD non-address DIP switches) for this zone until power is cycled.

*********************************************************************************

COMMAND:

*ZxxVRSTOFF<CR> – zone xx VOLUME RESET OFF.

RESPONSE:

Same response as for *ZxxSETSR<CR>

NOTE: sending this command to the E6D will set override (lock out KEYPAD non-address DIP switches) for this zone until power is cycled.

*********************************************************************************

COMMAND: *ZxxLKON<CR> – zone xx KEYPAD LOCK ON – This will INHIBIT ANY keypad control input on the zone.

This is the same as activating the Parental lock control at a keypad by holding down a SOURCE key for three seconds).

RESPONSE: #ZxxLKON<CR>

*********************************************************************************

COMMAND: *ZxxLKOFF<CR> – zone xx KEYPAD LOCK ON – This will RESTORE ALL keypad control input on the zone (useful as Parental lock control) . This is the same as de-activating the Parental lock control at a keypad by holding down a SOURCE key for three seconds).

RESPONSE: #ZxxLKOFF<CR>

*********************************************************************************

COMMAND: *VER<CR> – Firmware version query.

RESPONSE: #NUVO_E6D_vx.yy<CR> where x is the major version number and yy is the minor version number.

*********************************************************************************

RESPONSE: #EXTMON<CR> Issued whenever the External MUTE first activates (closure to ground) and 0 whenever the External MUTE de-activates (open connection to ground).

NOTE – there is no COMMAND associated with this response; it is always initiated by a change at the EXT. MUTE input.

*********************************************************************************

RESPONSE: #EXTMOFF<CR> Issued whenever External MUTE de-activates (open connection to ground).

NOTE – there is no COMMAND associated with this response; it is always initiated by a change at the EXT. MUTE input.