COMMAND: | *ZxxVRSTON<CR> – zone xx VOLUME RESET ON. |
RESPONSE: | Same response as for *ZxxSETSR<CR> |
NOTE: sending this command to the E6D will set override (lock out KEYPAD
*********************************************************************************
COMMAND: | *ZxxVRSTOFF<CR> – zone xx VOLUME RESET OFF. |
RESPONSE: | Same response as for *ZxxSETSR<CR> |
NOTE: sending this command to the E6D will set override (lock out KEYPAD
*********************************************************************************
COMMAND: *ZxxLKON<CR> – zone xx KEYPAD LOCK ON – This will INHIBIT ANY keypad control input on the zone.
This is the same as activating the Parental lock control at a keypad by holding down a SOURCE key for three seconds).
RESPONSE: #ZxxLKON<CR>
*********************************************************************************
COMMAND: *ZxxLKOFF<CR> – zone xx KEYPAD LOCK ON – This will RESTORE ALL keypad control input on the zone (useful as Parental lock control) . This is the same as
RESPONSE: #ZxxLKOFF<CR>
*********************************************************************************
COMMAND: *VER<CR> – Firmware version query.
RESPONSE: #NUVO_E6D_vx.yy<CR> where x is the major version number and yy is the minor version number.
*********************************************************************************
RESPONSE: #EXTMON<CR> Issued whenever the External MUTE first activates (closure to ground) and 0 whenever the External MUTE
NOTE – there is no COMMAND associated with this response; it is always initiated by a change at the EXT. MUTE input.
*********************************************************************************
RESPONSE: #EXTMOFF<CR> Issued whenever External MUTE
NOTE – there is no COMMAND associated with this response; it is always initiated by a change at the EXT. MUTE input.
30