OMB-DAQ-2416-4AO User's Guide

Specifications

Analog voltage output

Unused VDACx output channels should be left disconnected.

The OMB-DAQ-2416-4AO output voltage level defaults to 0 V whenever the host PC is reset, shut down or suspended, or if a reset command is issued to the device.

The duration of the output transient depends highly on the enumeration process of the host PC. Typically, the output of the OMB-DAQ-2416-4AO is stable after two seconds.

Table 20. Analog voltage output specifications

Parameter

 

 

Conditions

 

Specifications

 

 

 

 

 

 

 

 

 

Digital-to-analog

 

 

 

 

 

DAC8555

converter

 

 

 

 

 

 

 

 

 

Number of channels

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

Resolution

 

 

 

 

 

 

16 bits

 

 

 

 

 

 

 

 

 

 

 

 

Output ranges

 

 

Calibrated

 

 

±10 V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Uncalibrated

 

±10.05 V, software configurable

 

 

 

 

 

 

 

 

Output transient

 

Host PC is reset, powered on, suspended or a

Duration: 2 s

 

 

 

 

reset command is issued to device (Note 6)

Amplitude: 2 V p-p

 

 

 

 

 

 

 

 

 

 

 

 

 

Initial power on

 

Duration: 50 ms

 

 

 

 

 

 

 

 

Amplitude: 5 V peak

 

 

 

 

 

 

 

 

 

 

Differential

 

 

 

 

 

 

±0.25 LSB typical

non-linearity

 

 

 

 

 

 

±1 LSB maximum

 

 

 

 

 

 

 

 

 

Output current

 

 

VDACx pins

 

±3.5 mA maximum

 

 

 

 

 

 

 

 

Output short-circuit

 

VDACx connected to AGND

 

Unlimited duration

protection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output coupling

 

 

 

 

 

DC

 

 

 

 

 

 

 

 

 

 

VDACx readback

 

 

 

 

 

Each VDACx output can be independently

 

 

 

 

 

 

 

 

measured by the onboard A/D converter.

 

 

 

 

 

 

 

 

Software selectable

Power on and reset

 

 

 

 

 

DACs cleared to zero-scale: 0 V, ±50 mV

state

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output noise

 

 

 

 

 

 

30 µVrms

Settling time

 

 

To rated accuracy, 10 V step

 

45 µs

 

Slew rate

 

 

 

 

 

 

1.0 V/µs

 

 

 

 

 

 

 

 

 

 

Throughput

 

 

Single-channel

 

1000 S/s maximum, system-dependent

 

 

 

 

 

 

 

 

 

 

 

 

 

Multi-channel

 

1000 S/s / #ch maximum, system-dependent

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 21. Calibrated absolute accuracy specifications

 

 

 

 

 

 

 

 

 

Range

 

Accuracy (±LSB)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

±10 V

 

16.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 22. Calibrated absolute accuracy components specifications

 

 

 

 

 

 

 

Range

 

% of reading

 

Offset (±mV)

Temp drift (%/°C)

 

Absolute accuracy at FS (±mV)

 

 

 

 

 

 

 

 

 

 

 

±10 V

 

±0.0183

 

 

 

1.831

0.00055

 

 

3.661

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 23. Relative accuracy specifications

 

 

 

 

 

 

 

Range

 

Relative accuracy (±LSB)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

±10 V

 

4.0 typical

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40