Installing the Transmitter

1. Disconnect electrical power from the target sys-
tem before making or changing any transmitter
connections.
2. Use 0.05Afast acting fuse if non-current limited
power sources are utilized.
3. Terminate cable shield connection at either DC
ground or Earth ground.
4. Mount the transmitter so fluid is traveling in the
direction of the flow arrow. See Figure 5.
5. Install unit in desired location. Use wrench on
transmitter flats to hold the unit in place during
installation. DO NOTTURN the transmitter
using the wrench. See Figure 6.
6. After installation, rotate transmitter by hand to
view display. See Figure 7.
7. Capture the zero flow position on the meter
cone using the ZERO CAPTURE procedure
found on page 12.
IV. OPERATION

NOTE: Refer to the Appendix for application informa-

tion and fluid charts.

Operating the Meter

The monitor has two modes of operation, referred to
as RUN mode and PROGRAM mode as indicated on
the display screen readout. Normal operation will be in
the run mode. To access the program mode, press the
MENU key until the first programming screen
DISPLAYappears. (PROGRAM appears on left side of
display.) After programming the meter a password may
be entered to prevent unauthorized access or chang-
ing of the setup features.

Normal Operation (RUN) Mode

During normal operation, the display will show RUN
and the flow rate, total flow, or toggle back and forth
between the two as defined by the DISPLAYconfigu-
ration.
The 4 buttons have the following function in RUN
mode:
MENU - Selects programming mode.
UPARROW - No function.
RIGHTARROW - No function.

FLR Flow Transmitter

Installation & Programming Instructions

Page 6

Figure 5. Flow Direction Arrow

Place wrench on
transmitter flats on the
same sideplumbing is
being tightened
Neverplace wrench
on transmitter flats
opposite plumbing
being tightened

Figure 6. Installing Transmitter

Neveruse wrench to
rotate transmitter
body when viewing
flow display
Rotate transmitter by
hand to view flow
display

Figure 7. Rotating Transmitter

FLOW
INLET PORT
FLR