3.3.6Interrupt Polarity Control Register

(Read/Write): wBase+0x2A

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

0

0

0

0

INV3

INV2

INV1

INV0

Note. Refer to Sec. 3.1 for more information about wBase.

INV0=1Æ select the non-inverted signal from P2C0

INV0=0Æ select the inverted signal from P2C0

outportb(wBase+0x2a,0x0f);

/* select the non-inverted input P2/5/8/11C0

*/

outportb(wBase+0x2a,0x00);

/* select the inverted input of P2/5/8/11C0

*/

outportb(wBase+0x2a,0x0e); /* select the inverted input of P2C0

*/

 

/* select the non-inverted input P5/8/11C0

*/

outportb(wBase+0x2a,0x0c); /* select the inverted input of P2/5C0

*/

 

/* select the non-inverted input P8/11C0

*/

Refer to Sec. 2.5 for more information.

Refer to DEMO5.C for more information.