2.11.1 User Levels

There are three user levels for gaining direct access to the recorder. User levels are only active if security is enabled. The three levels are

Administrator: Has access to all levels of the recorder menus and systems.

Manager: Has restricted access. A Manager cannot set up any base level parameters, but can use existing setups to create alarms, displays and the like.

User:Can use the recorder only as set up by the Administrator or Manager. A User cannot change any parameters. A User needs to log in to accept alarms.

User management is an Administrative only function and is controlled in the System Administrative Menu. Here the Administrator can set usernames and passwords, disable users, set user expiry times and force a user to be logged out after a specific time. The number of log in attempts can also be set before the current user is disabled.

All users need to log in to the unit to perform any functions. At each log in the recorder makes a note of the time and user name and will also log any failed attempts at login. Each user has a unique username and password. Users may change their passwords at any time at the log in screen.

The unit also saves a copy of the configuration file when the user logs in and when the user logs out. This way a complete activity log can be generated (by the accompanying Exhibitor software comparing the two configuration files) and all parameters changed can be reported.

2.11.2 Remote Access Passwords

The user can access the recorder remotely using various methods. Each method is protected by a unique password. The passwords need to be set up by the Administrator in the System Administrative Menu as follows:

USB Access: Password optional. When accessing the unit via the USB Connection using ActiveSyncTM or VistaTM Mobile Manager the Administrator can set an optional password which needs to be entered from the remote computer before access is allowed. This password is set in the Set ActiveSync Password menu.

HTTP Access: Password required. When accessing the web server using the Ethernet and a browser the user has to provide a password. There are two levels of password Admin and User. Users can view the web pages but only Admin can perform remote functions. These passwords are set in the Web User Manager and the Administrator user name HAS to be Admin.

FTP Access: Password Required. This is the same Admin password used for HTTP Access. No User access is permitted.

Remote Control over Ethernet: Password Required. These are the same user names and passwords set for recorder front panel access through the User management option described above.

All access user names and passwords can be set to be the same provided the administrator user name is Admin. However you do have to set these up at the various locations referred to above.

Page 12

09/11/2008 REV 0.99

Page 21
Image 21
Omega Speaker Systems RD8300 manual User Levels, Remote Access Passwords

RD8300 specifications

The Omega Speaker Systems RD8300 is a remarkable entry in the audio equipment market, designed for audiophiles and casual listeners alike who seek high-quality sound reproduction. This speaker system combines cutting-edge technologies with user-friendly features to deliver an immersive listening experience.

One of the standout characteristics of the RD8300 is its advanced driver configuration. Featuring a dual 8-inch woofers, a precision-tuned midrange driver, and a high-frequency tweeter, the RD8300 is engineered to provide a full range of frequencies with unparalleled clarity. This configuration ensures that bass notes are deep and powerful, while mid-range and treble sounds are crisp and detailed, making it suitable for a wide variety of music genres and audio formats.

Another integral technology in the RD8300 is its sophisticated crossover network. By intelligently directing frequencies to the appropriate drivers, the crossover helps to minimize distortion and enhance the overall sonic coherence of the speaker. This ensures every note is delivered with precision, allowing listeners to appreciate the nuances in their favorite tracks.

The RD8300 also boasts an impressive power handling capability, allowing it to deliver loud and dynamic sound without compromising audio quality. Its robust construction ensures minimal resonance, further enhancing sound clarity. The speaker's enclosure is crafted from high-density fiberboard, designed to reduce unwanted vibrations while maximizing audio performance.

In terms of connectivity, the RD8300 is versatile. It comes equipped with standard binding post inputs, making it compatible with a wide range of audio equipment. Additionally, it features both wired and wireless connectivity options, catering to modern listening preferences.

User convenience is another focus of the RD8300's design, with features such as adjustable feet and a user-friendly interface that allows for easy setup and adjustment. The sleek visual design of the speaker adds an aesthetic touch, making it an attractive addition to any room.

In summary, the Omega Speaker Systems RD8300 stands out as an exceptional speaker choice. With its advanced driver design, sophisticated crossover technology, impressive power handling, versatile connectivity options, and user-friendly features, it caters to those seeking a superior audio experience, making it a must-have for audio enthusiasts.