Omega Speaker Systems wi Series manual Factory Preset Values, Input, Setpoints & On/Off Control

Models: wi Series

1 96
Download 96 pages 9.02 Kb
Page 82
Image 82

PART 7

FACTORY PRESET VALUES

To set the Wireless and Ethernet settings back to Factory Default do the following to the DIP switches (see Figure 2.11).

To set the Ethernet board to Factory Default settings:

 

1) Put the 4 position DIP switch #2 to ON position (it does not matter if the Meter

is On or Off).

 

 

2) Power-cycle the Meter andwait about 10 seconds until the Meter fully boots up.

3) Put the DIP switch #2 back to OFF position (it does not matter if the Meter is

powered On or Off, just make sure that the DIP switch is set to OFF,

otherwise, everytime the unit is power-cycled the factory settings will take

over.

 

 

To set the Wireless board to Factory Default settings:

 

1) Put the 8 position DIP switch #1 to ON position (it does not matter if the Meter

is On or Off).

 

 

2) Power-cycle the Meter andwait about 10 seconds until the Meter fully boots up.

3) Put the DIP switch #1 back to OFF position (it does not matter if the Meter is

powered On or Off, just make sure that the DIP switch is set to OFF,

otherwise, everytime the unit is power-cycled the factory settings will take

over.The defaults that will change are noted by a “W” or “E” in the Table below.

The defaults for the Meter/Controller “C” are set by the individual Setup

menus.

 

 

C = Meter/Controller Board

 

 

W = Wireless or Coordinator Board

 

E = Ethernet or iServer Board

 

 

Table 7.1 Factory Preset Values

 

 

CONTROLLER SETUP

 

 

Input

1

W

Control End Device ID

Filter

4

C

Temperature Unit

F

C

Setpoints & On/Off Control

C

Auto Setpoint Deviation

Disabled

Setpoint 1

0

C

Setpoint 2

100

C

Permanent Store

￿

C

76

Page 82
Image 82