Omnitron Systems Technology 10/100M2 user manual Enabling/Disabling Soft-switch Reload

Models: 10/100M2

1 47
Download 47 pages 26.81 Kb
Page 19
Image 19

3.4.3Enabling/Disabling Soft-switch Reload

The Soft-switch Reload function controls the configurations of the 10/100M2 and other iConverter modules managed by the 10/100M2 following a power up.

When the Soft-switch Reload is disabled, the configurations of the 10/100M2 and the other managed modules (non-management modules) are determined by their hardware DIP-switch settings following a return of power.

When the Soft-switch Reload is enabled, the configurations of the 10/100M2 and the other managed modules are determined by the previous software settings stored in the FLASH memory of the 10/100M2 following a return of power. Each of the hardware DIP-switch settings on the module are ignored until a change is made to the DIP-switch, then the hardware settings will take effect.

To set the Soft-switch Reload function, select 8 at the IP and Control Preferences screen, press <ENTER> and then follow the screen prompts to change the setting.

PI

SA

IP and Control Preferences Screen

iConverter, Serial Agent

1:

Set IP

 

192.168.1.220

2:

Set Subnet Mask

255.255.255.0

3:

Set Gateway

192.168.1.1

4:

Chassis Number

1

5:

Chassis Name (also sysName)

10/100M2

6:

Enable/Disable TELNET

Enabled

7:

Enable/Disable FTP

Disabled

8:

Enable/Disable Soft Switch Reload

Disabled

9:

TELNET Password

*****

10: FTP

Password

 

11: Serial Password

 

Enter Choice, Management Options Screen(0), (H)elp, E(x)it >

To save the new values, select 0 and press <ENTER> to return to the Management Options screen, then select 6 and press <ENTER> to Save Preference Changes.