3.2.2
PI
DIP-switch Bank 2 is only available on the plug-in module.
Switch | Left (Factory Default) | Right |
SW1 | ||
| Backplane Port A Disabled | Port A Enabled |
SW2 | ||
| Backplane Port B Disabled | Port B Enabled |
SW3 | Reserved | Reserved |
SW4 | M/SL: | SL: |
| Master/Slave | |
SW5 - SW8 | Reserved | Reserved |
3.2.2.1SW1 - Backplane Port A Enabled
When the
3.2.2.2SW2 - Backplane Port B Enabled
When the
3.2.2.3SW4 - Master/Slave
When multiple management modules such as the iConverter NMM and the 10/100M2 (or multiple self- managed modules such as the 10/100M2) are installed in the same chassis, only one management module can act as the chassis master. The master management module has the ability to make changes to the settings of the other modules in the chassis, while the slave management modules cannot make the changes. If an NMM is installed in the chassis, the NMM will always be the master, otherwise the lowest slot number with a management module installed will become chassis master.
When this
Only the chassis master can change configuration settings of other modules.
3.2.2.4SW3, SW5, SW6, SW7, SW8 - Reserved
These DIP-switches are for factory use only.
NOTE: