User Manual

UMN:CLI

SURPASS hiD 6615 S223/S323 R1.5

 

 

 

 

 

To configure flow control of the Ethernet port, use the following command.

Command

Mode

Description

 

 

 

port flow-control PORTS {on

Bridge

Configures flow control for a specified port, enter the

off}

port number. (default: off)

 

 

 

 

The following is an example of configuring flow control to port 25.

SWITCH(bridge)# show port 25

------------------------------------------------------------------------

NO TYPE PVID STATUS MODE FLOWCTRL INSTALLED (ADMIN/OPER)

------------------------------------------------------------------------

25 Ethernet

1

Up/Down Auto/Half/0

SWITCH(bridge)# port flow-control 25 on

SWITCH(bridge)# show port 25

Off

Y

-------------------------------------------------------------------

NO

TYPE

PVID

STATUS

MODE

FLOWCTRL INSTALLED

 

 

(ADMIN/OPER)

 

 

-------------------------------------------------------------------

 

25: Ethernet

1

Up/Down Auto/Half/0

On

Y

SWITCH(bridge)#

 

 

 

 

 

 

 

 

5.2.6Port Description

To specify a description of an Ethernet port, use the following command.

Command

Mode

Description

 

 

 

port description PORTS

 

Specifies a description of an Ethernet port.

DESCRIPTION

Bridge

 

 

 

 

no port description PORTS

 

Deletes description of specified port.

 

 

 

To view description of port, use the following command.

Command

Mode

Description

 

 

 

 

Enable

 

show port description PORTS

Global

Shows description of one port or more.

Bridge

 

 

 

Interface

 

 

 

 

The following is an example of making description of port 1 and viewing it.

SWITCH(bridge)# port description 1 test1

SWITCH(bridge)# show port description 1

------------------------------------------------------------

NO TYPE

STATE

LINK

DESCRIPTION

 

(ADM/OPR)

 

 

------------------------------------------------------------

1 Unknown

Up/Down

0HDX test1

SWITCH(bridge)#

 

 

A50010-Y3-C150-2-7619

77

Page 77
Image 77
Siemens S223, S323 user manual Port Description, Following is an example of configuring flow control to port