User Manual

UMN:CLI

SURPASS hiD 6615 S223/S323 R1.5

 

 

 

 

 

place with TCP/IP through SNMP or telnet, it requires IP address.

You can enable interface to communicate with switch interface on network and assign IP address as the following:

Enabling Interface

Disabling Interface

Assigning IP Address to Network Interface

Static Route and Default Gateway

Displaying Forwarding Information Base(FIB) Table

Forwarding Information Base(FIB) Retain

Displaying Interface

Sample Configuration

4.3.1Enabling Interface

To assign an IP address to an interface, you need to enable the interface first. If the inter- face is not enabled, you cannot access it from a remote place, even though an IP address has been assigned.

To display if interface is enabled, use the command, show running-config.

Interface Configuration Mode

To open Interface Configuration mode of the interface you are about to enable interface, use the following command.

Command

Mode

Description

 

 

 

interface INTERFACE

Global

Opens Interface Configuration mode of the interface.

 

 

 

To enable the interface, use the following command.

Command

Mode

Description

 

 

 

no shutdown

Interface

Enables the interface on Interface Configuration mode.

 

 

 

The following is an example of enabling interface on Interface Configuration mode.

SWITCH# configure terminal

SWITCH(config)# interface 1

SWITCH(config-if)# no shutdown

SWITCH(config-if)#

4.3.2Disabling Interface

To disable the interface, use the following commands on Interface Configuration mode. Before disabling interface on Interface Configuration mode, you should open the mode, and then use the follow command.

Command

Mode

Description

 

 

 

shutdown

Interface

Disables an interface on Interface Configuration mode.

 

 

 

A50010-Y3-C150-2-7619

57

Page 57
Image 57
Siemens S223, S323 user manual Enabling Interface, Disabling Interface, Interface Configuration Mode