User Manual

UMN:CLI

SURPASS hiD 6615 S223/S323 R1.5

 

 

 

 

 

To configure BPDU guard in the switch, perform the following procedure.

Step 1

Configure the specific port as edge-port.

Command

Mode

Description

 

 

 

stp edge-port PORTS

Bridge

Configures the port as Edge port.

 

 

no stp edge-port PORTS

Disables Edge port configuration.

 

 

 

 

Step 2

Configure BPDU Guard.

Command

Mode

Description

 

 

 

stp bpdu-guard

Bridge

Configures BPDU Guard function on switch.

 

 

no stp bpdu-guard

Disables BPDU Guard function.

 

 

 

 

However, BPDU Guard can be corrupted by unexpected cause. In this case, the edge port is blocked immediately and remains at this state until user recovers it. To prevent this problem, the hiD 6615 S223/S323 switch provides BPDU guard auto-recovery function. When an edge port is down for BPDU packet which came from other switch, the port is recovered automatically after configured time.

To configure BPDU Guard auto-recovery, use the following command.

Command

Mode

Description

 

 

 

stp bpdu-guard auto-recovery

 

Configures BPDU Guard auto-recovery on switch.

 

 

 

stp bpdu-guard auto-recovery-

 

Configures BPDU Guard auto-recovery-time.

time <10-1000000>

 

 

 

 

Bridge

 

no stp bpdu-guard auto-

 

recovery

 

Disables BPDU Guard auto-recovery function.

 

 

no stp bpdu-guard auto-

 

 

 

recovery-time

 

 

 

 

 

To recover a blocked port by manually, use the following command.

Command

Mode

Description

 

 

 

stp bpdu-guard err-recovery

Bridge

Recovers a blocked port by manually.

PORTS

 

 

 

 

 

8.3.9.7Self Loop Detection

Although there is no double path in user’s equipment, loop can be caused by network en- vironment and cable condition connected to equipment. To prevent this, the hiD 6615 S223/S323 has self loop detection to perceive that outgoing packet is got back. Through the self loop detection, you can prevent packet, which comes back because it blocks the port.

A50010-Y3-C150-2-7619

223

Page 223
Image 223
Siemens S223, S323 user manual Self Loop Detection, Configure the specific port as edge-port, Configure Bpdu Guard