User Manual

UMN:CLI

SURPASS hiD 6615 S223/S323 R1.5

 

 

 

 

 

leged EXEC Enable mode; however as level 1, it is possible to use not only the com- mands in level 1 but also time configuration commands in Privileged EXEC Enable mode and accessing commands to Global Configuration mode.

4.1.5Limiting Number of User

For hiD 6615 S223/S323, you can limit the number of user accessing the switch through both console port and telnet. In case of using the system authentication with RADIUS or TACACS+, the configured number includes the number of user accessing the switch via the authentication server.

To set the number of user accessing the switch, use the following command.

Command

Mode

Description

 

 

 

login connect <1-8>

Global

Sets the number of user accessing the switch.

Default: 8

 

 

 

 

 

4.1.6Telnet Access

To connect to the host through telnet at remote place, use the following command.

Command

Mode

Description

 

 

 

telnet DESTINATION [TCP-PORT]

Enable

Connects to a remote host.

DESTINATION: IP address or host name

 

 

 

 

 

In case of telnet connection, you should wait for [OK] message, when you save a system

! configuration. Otherwise, all changes will be deleted when the telnet session is discon- nected.

SWITCH# write memory

[OK]

SWITCH#

The system administrator can disconnect users connected from remote place. To discon- nect a user connected through telnet, use the following command.

Command

Mode

Description

 

 

 

disconnect TTY-NUMBER

Enable

Disconnects a user connected through telnet.

 

 

 

The following is an example of disconnecting a user connected from a remote place.

SWITCH# where

 

admin at from console for 4 days 22 hours 15

minutes 24.88 seconds

admin at ttyp0 from 10.0.1.4:1670 for 4 days

17 hours 53 minutes 28.76 seconds

admin at ttyp1 from 147.54.140.133:49538 for

6 minutes 34.12 seconds

SWITCH# disconnect ttyp0

 

SWITCH# where

 

admin at from console for 4 days 22 hours 15

minutes 34.88 seconds

admin at ttyp1 from 147.54.140.133:49538 for

6 minutes 44.12 seconds

SWITCH#

 