User Manual

UMN:CLI

SURPASS hiD 6615 S223/S323 R1.5

 

 

 

 

 

snmp trap dhcp-lease

snmp trap fan

snmp trap power

snmp trap module

Global

Configures the system to send SNMP trap when no more IP address that can be assigned in the subnet of DHCP server is left.

Configures the system to send SNMP trap when the fan begins to operate or stops.

Configures the system to send SNMP trap when any problem occurs in power.

Configures the system to send SNMP trap when there is any problem in module.

7.1.8.4Disabling SNMP Trap

To disable SNMP trap, use the following command.

Command

Mode

Description

 

 

 

no snmp trap auth-fail

 

 

 

 

 

no snmp trap cold-start

 

 

 

 

 

no snmp trap link-up PORTS

 

 

[NODE]

 

 

 

 

 

no snmp trap link-down PORTS

 

 

[NODE]

 

 

 

 

 

no snmp trap cpu-threshold

Global

Disables each SNMP trap.

no snmp trap port-threshold

 

 

 

 

 

no snmp trap temp-threshold

 

 

 

 

 

no snmp trap dhcp-lease

 

 

 

 

 

no snmp trap fan

 

 

 

 

 

no snmp trap power

 

 

 

 

 

no snmp trap module

 

 

 

 

 

When you use the no snmp command, all configurations concerning SNMP will be

! deleted.