6.1.12.4System Temperature

To set a threshold of system temperature, use the following command.

Command

Mode

Description

 

 

 

 

 

Sets a threshold of system temperature in the unit of

threshold temp VALUE VALUE

Global

centigrade (°C).

 

VALUE: Threshold temperature between -40 ~ 100

 

 

 

 

 

no threshold temp

 

Deletes a configured threshold of system temperature.

 

 

 

To show a configured threshold of system temperature, use the following command.

Command

Mode

Description

 

 

 

show status temp

Enable

Shows a status and configured threshold of system

Global

temperature.

 

 

 

 

6.1.12.5System Memory

To set a threshold of system memory in use, use the following command.

Command

Mode

Description

 

 

 

 

 

Sets a threshold of system memory in the unit of per-

threshold memory <20-100>

Global

cent (%).

 

20-100: system memory in use

 

 

 

 

 

no threshold memory

 

Deletes a configured threshold of system memory.

 

 

 

6.1.13Enabling FTP Server

FTP server is enabled on hiD 6615 S223/S323 by default. But this configuration can’t provide the security serveice becaue it’s easy to access to the port #23 by others. If the default configuration is unnecessary on sysem, user can disable the system as FTP server.

To enable/disable the system of hiD S223/S323 as FTP server, use the following com- mand.

Command

Mode

Description

 

 

 

ftp server {enabledisable}

Global

Enables/ disables the function for FTP serve

Default: enable

 

 

 

 

 

The follwing is an example of displaying the status of FTP server.

SWITCH(config)# ftp server disable

SWITCH(config)# show running-config

(Omitted)

!

ftp server disable (Omitted) SWTICH(config)#