UMN:CLI

User Manual

 

SURPASS hiD 6615 S223/S323 R1.5

 

 

 

To configure interval of sample inquiry for RMON alarm, use the following command.

Command

Mode

Description

 

 

 

sample-interval <0-65535>

RMON

Configures interval of sample inquiry.

(unit: second)

 

 

 

 

 

7.4.2.8Activating RMON Alarm

After finishing all configurations, you need to activate RMON alarm. To activate RMON alarm, use the following command.

Command

Mode

Description

 

 

 

active

RMON

Activates RMON alarm.

 

 

 

7.4.2.9Deleting Configuration of RMON Alarm

When you need to change a configuration of RMON alarm, you should delete an existing RMON alarm.

To delete RMON alarm, use the following command.

Command

Mode

Description

 

 

 

no rmon-alarm <1-65535>

Global

Deletes RMON history of specified number, enter the

value for deleting.

 

 

 

 

 

7.4.2.10Displaying RMON Alarm

To display RMON alarm, use the following command.

Command

 

Mode

Description

 

 

 

 

show running-config

rmon-

All

Shows a configured RMON alarm.

alarm

 

 

 

 

 

 

 

 

7.4.3RMON Event

RMON event identifies all operations such as RMON alarm in the switch. You can config- ure event or trap message to be sent to SNMP management server when sending RMON alarm.

You need to open RMON Event Configuration mode to configure RMON event.

Command

Mode

Description

 

 

 

rmon-event <1-65535>

Global

Opens RMON Event Configuration mode.

1-65535: index number

 

 

 

 

 

7.4.3.1Event Community

When RMON event is happened, you need to input community to transmit SNMP trap message to host. Community means a password to give message transmission right.

132

A50010-Y3-C150-2-7619

Page 132
Image 132
Siemens S323, S223 Rmon Event, Activating Rmon Alarm, Deleting Configuration of Rmon Alarm, Displaying Rmon Alarm