User Manual

 

 

 

 

 

 

 

UMN:CLI

SURPASS hiD 6615 S223/S323 R1.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 5.2 Port Mirroring

To configure port mirroring, designate mirrored ports and monitor port. Then enable port mirroring function. Monitor port should be connected to the watch program installed PC. You can designate only one monitor port but many mirrored ports for one switch.

Step 1

Activate the port mirroring, using the following command.

Command

Mode

Description

 

 

 

mirror enable

Bridge

Activates port mirroring.

 

 

 

Step 2

Designate the monitor port, use the following command.

Command

Mode

Description

 

 

 

mirror monitor {PORTS I cpu}

Bridge

Designates the monitor port.

 

 

 

Step 3

Designate the mirrored ports, use the following command.

Command

Mode

Description

 

 

 

mirror add PORTS [ingress

 

Designates the mirrored ports.

Bridge

ingress: ingress traffic

egress]

 

egress: egress traffic

 

 

 

 

 

A50010-Y3-C150-2-7619