User Manual

UMN:CLI

SURPASS hiD 6615 S223/S323 R1.5

 

 

 

 

 

8.9.3.6Manual Switch to Secondary

To configure Manual Switch to Secondary, use the following command.

Command

Mode

Description

 

 

 

erp ms-s DOMAIN-ID

Bridge

Configures ERP manual switch to secondary

 

 

 

To disable Manual Switch to Secondary, use the following command.

Command

Mode

Description

 

 

 

no erp ms-s DOMAIN-ID

Bridge

Disables ERP manual switch to secondary

 

 

 

8.9.3.7Wait-to-Restore Time

To configure Wait-to-Restore Time, use the following command.

Command

Mode

Description

 

 

 

erp wait-to-restore DOMAIN-ID

Bridge

Configures ERP wait-to-restore time

<1-720>

1-720: Wait to restore time in second

 

 

 

 

To return the configured Wait-to-Restore Time as Default, use the following command.

Command

Mode

Description

 

 

 

no erp wait-to-restore DOMAIN-

Bridge

Configures ERP wait-to-restore time as default value

ID

 

 

 

 

 

8.9.3.8Learning Disable Time

To configure ERP Learning Disable Time, use the following command.

Command

Mode

Description

 

 

 

erp learn-dis-time DOMAIN-ID

Bridge

Configures ERP learning disable time

<0-500>

0-500: learning disabling time (unit: millisecond)

 

 

 

 

To return the configured Learning Disable Time as Default, use the following command.

Command

Mode

Description

 

 

 

no erp learn-dis-time DOMAIN-ID

Bridge

Configures ERP learning disable time as default value

 

 

 

8.9.3.9Test Packet Interval

To configure ERP Test Packet Interval, use the following command.

Command

Mode

Description

 

 

 

erp test-packet-interval DO-

Bridge

Configures ERP test packet interval

MAIN-ID <10-500>

10-500: packet interval (unit: millisecond)

 

 

 

 

A50010-Y3-C150-2-7619