Siemens S323, S223 user manual Object of Sample Inquiry, Absolute Comparison and Delta Comparison

Models: S323 S223

1 381
Download 381 pages 49.11 Kb
Page 130
Image 130

UMN:CLI

User Manual

 

SURPASS hiD 6615 S223/S323 R1.5

 

 

 

7.4.2.2Object of Sample Inquiry

User needs object value used for sample inquiry to provide RMON Alarm. The following is rule of object for sample inquiry. To assign object used for sample inquiry, use the follow- ing command.

Command

Mode

Description

 

 

 

sample-variable MIB-OBJECT

RMON

Assigns MIB object used for sample inquiry.

 

 

 

7.4.2.3Absolute Comparison and Delta Comparison

It is possible to select the way to compare MIB object used for sample inquiry in case of configuring RMON Alarm. Absolute comparison directly compares object selected as sample with the threshold. For instance, when you want to know the point of 30,000 times of sample inquiry, if you configure apSvcConnections as 30,000, it is for Absolute com- parison. To compare object selected as sample with the threshold, use the following command.

Command

Mode

Description

 

 

 

sample-type absolute

RMON

Compares object with the threshold directly.

 

 

 

Delta comparison compares difference between current data and the latest data with the threshold. For instance, in order to know the point of variable notation rule 100,000 more than the former rule, configure apCntHits as Delta comparison. To configure delta com- parison, use the following command.

Command

Mode

Description

 

 

 

sample-type delta

RMON

Compares difference between current data and the

latest data with the threshold.

 

 

 

 

 

7.4.2.4Upper Bound of Threshold

If you need to occur alarm when object used for sample inquiry is more than upper bound of threshold, you have to configure the upper bound of threshold. To configure upper bound of threshold, use the following command.

Command

Mode

Description

 

 

 

rising-threshold VALUE

RMON

Configures upper bound of threshold.

VALUE: 0-2147483647

 

 

 

 

 

After configuring upper bound of threshold, configure to generate RMON event when ob- ject is more than configured threshold. Use the following command.

Command

Mode

Description

 

 

 

 

 

Configures to generate RMON event when object is

rising-event <1-65535>

RMON

more than configured threshold.

 

 

1-65535: event index

 

 

 