5Maintenance and Troubleshooting

The lamp should be replaced when it reaches the end of its life (typically 2000 hours), or sooner if a noticeable degradation in brightness occurs. When you replace a lamp, you should replace the filters as well.

For lamp or filter replacement, please contact your nearest Vidikron authorized service center or Vidikron dealer. Do not attempt to replace the lamp yourself!

WARNING

The Vision 110 lamp is under high pressure. Handle it with great care at

all times. Lamps may explode if dropped or mishandled.

Never attempt to disassemble the lamp casing or dispose of the lamp casing in any manner other than by returning it to your Vidikron dealer.

If the lamp breaks, leave the area immediately and stay away for at least 30 minutes. Ventilate the room to allow the mercury vapor to disperse.

If you inhale the mercury vapor, see a physician immediately.

5.1

Lamp Replacement

1.Turn off the projector and unplug the power cord. Allow the projector to cool down for approximately 45 minutes prior to removing the lamp assembly for replacement.

2.Loosen and remove the rear Lamp Cover screw.

3.Slide the Lamp Cover in the direction of the arrow to remove it.

4.Loosen the two, captive lamp assembly mounting

screws using a coin or a large, flat-blade screwdriver.

5.Grasp the lamp assembly handle and pull gently, removing the lamp module from the projector housing.

Vidikron Vision Model 110 Installation/Operation Manual

59

Page 73
Image 73
Vidikron Vision 110 operation manual 5Maintenance and Troubleshooting, Lamp Replacement