CineWide with AutoScope maintains constant image height independent of the aspect ratio,

Configure Lens Motor Trigger

while using the full display resolution of the projector. It accomplishes this by moving the

 

anamorphic lens in front of the primary lens when widescreen material is being viewed.

 

When the viewer transitions back to 16:9 or 4:3 source material, the anamorphic lens moves

 

out of the light path.

 

To configure the lens motor trigger on the Vision 110 for proper AutoScope operation:

 

1.

Project a 2.35:1 aspect ratio test pattern or other image on the screen.

 

2.

Press MENU on the remote control and enter the Service menu passcode.

 

3.

Select Service from the Main menu.

 

4.

Select Triggers from the Service menu.

 

5.

Assign the trigger output to which the lens motor is connected to the Cinema and

 

 

IntelliWide 2.35 aspect ratios. This enables the lens motor to move the anamorphic lens

 

 

into position (in front of the primary lens) when either aspect ratio is selected.

 

6.

To save the trigger settings, press repeatedly to highlight “Save.” Then, press ENTER.

 

7.

Select the Cinema aspect ratio to move the anamorphic lens into position, if it isn’t

 

 

already. To do this, press CINEMA on the Vision 110 remote control (Figure 2-4), or press

 

 

or repeatedly with no menus visible on-screen.

 

Adjusting the Horizontal (X) Lens Position:

Adjust the Anamorphic Lens

1.Project a white field on the screen.

2.Loosen the Yaw/X-Adjustment Levers underneath the lens.

3.Slowly move the anamorphic lens into place so that there are no shadows on either side of the screen:

Too Far Left

Correct position

Too Far Right

4.When the horizontal position is properly set, tighten the Yaw/X-Adjustment Levers to secure the lens in place.

Vidikron Vision Model 110 Installation/Operation Manual

41

Page 55
Image 55