User Manual

 

UMN:CLI

SURPASS hiD 6615 S223/S323 R1.5

 

 

Normal Node

 

Normal Node

3. Unblock the

 

port recovered

 

from Link Failure

2. Send RM Link Up message

 

 

S

 

 

1. Block RM Node of

 

 

secondary port

 

 

P

Normal Node

2. Send RM Link

RM Node

 

Up message

 

Fig. 8.38 Ring Recovery

 

8.9.2Loss of Test Packet (LOTP)

ERP recognizes the Link Failure using Loss of Test Packet (LOTP). RM Node regularly sends RM Test Packet message. If the message is not retransmitted to RM Node through Ethernet Ring, it means that Loop doesn’t occur. Therefore, RM Node unblocks Secon- dary port. The condition that RM Test Packet from RM Node doesn’t return is LOTP state.

On the other hand, if RM Test Packet is retransmitted to RM Note through Ethernet Ring, Loop may occur. In this condition, RM Node blocks Secondary port.

8.9.3Configuring ERP

8.9.3.1ERP Domain

To realize ERP, you should fist configure domain for ERP. To configure the domain, use the following command.

Command

Mode

Description

 

 

 

erp domain DOMAIN-ID

 

Creates ERP domain.

Bridge

DOMAIN-ID: control VLAN ID of domain <1-4094>

 

 

 

 

no erp domain {all DOMAIN-ID}

 

Deletes ERP domain.

 

 

 

To specify a description for configured domain, use the following command.

Command

Mode

Description

 

 

 

erp description DOMAIN-ID

Bridge

Specifies a description of domain.

DESCRIPTION

 

 

 

 

 

A50010-Y3-C150-2-7619

267

Page 267