7.1.8.3Enabling SNMP Trap

i

The system provides various kind of SNMP trap, but it may inefficiently work if all these trap messages are sent very frequently. Therefore, you can select each SNMP trap sent to an SNMP trap host.

The system is configured to send all the SNMP traps as default.

authentication-failureis shown to inform wrong community is input when user trying to access to SNMP inputs wrong community.

cold-startis shown when SNMP agent is turned off and restarts again.

link-up/downis shown when network of port specified by user is disconnected, or when the network is connected again.

memory-thresholdis shown when memory usage exceeds the threshold specified by user. Also, when memory usage falls below the threshold, trap message will be shown to notify it.

cpu-thresholdis shown when CPU utilization exceeds the threshold specified by user. Also, when CPU load falls below the threshold, trap message will be shown to notify it.

port-thresholdis shown when the port traffic exceeds the threshold configured by user. Also, when port traffic falls below the threshold, trap message will be shown.

temperature-thresholdis shown when the system temperature exceeds the thresh- old configured by user. Also, when system temperature falls below the threshold, trap message will be shown.

dhcp-leaseis shown when there is no more IP address can be assigned in subnet of DHCP server. Even if only one subnet does not have IP address to assign when there are several subnets, this trap message will be seen.

fan/power/module is shown when there is any status-change of fan, power, and module.

To enable SNMP trap, use the following command.

Command

 

Mode

Description

 

 

 

 

snmp trap auth-fail

 

 

Configures the system to send SNMP trap when SNMP

 

 

authentication is fail.

 

 

 

 

 

 

 

snmp trap cold-start

 

 

Configures the system to send SNMP trap when SNMP

 

 

agent restarts.

 

 

 

 

 

 

 

snmp trap link-up

PORTS

 

Configures the system to send SNMP trap when a port

[NODE]

 

 

is connected to network.

 

 

 

snmp trap link-down PORTS

Global

Configures the system to send SNMP trap when a port

[NODE]

 

is disconnected from network.

 

 

 

 

 

 

snmp trap cpu-threshold

 

 

Configures the system to send SNMP trap when CPU

 

 

load exceeds or falls below the threshold.

 

 

 

 

 

 

 

snmp trap port-threshold

 

 

Configures the system to send SNMP trap when the

 

 

port traffic exceeds or falls below the threshold.

 

 

 

 

 

 

 

snmp trap temp-threshold

 

Configures the system to send SNMP trap when sys-

 

tem temperature exceeds or falls below the threshold.

 

 

 

 

 

 

 

 

 

 

 