The following is to configure to enable OAM loopback function through 25 port of the switch and operate once.

SWITCH(bridge)# oam local admin enable 25

SWITCH(bridge)# oam remote loopback enable 25

SWITCH(bridge)# show oam local 25

LOCAL PORT[25]

-------------------------------------------

item value

-------------------------------------------

admin

ENABLE

mode

ACTIVE

mux action

FORWARD

par action

DISCARD

variable

UNSUPPORT

link event

UNSUPPORT

loopback

SUPPORT(disable)

uni-direction

UNSUPPORT(disable)

-------------------------------------------

SWITCH(bridge)# show oam remote 25 REMOTE PORT[25]

-------------------------------------------

item value

-------------------------------------------

mode

ACTIVE

MAC address

00:d0:cb:27:00:94

variable

UNSUPPORT

link event

UNSUPPORT

loopback

SUPPORT(enable)

uni-direction

UNSUPPORT

-------------------------------------------

SWITCH(bridge)# oam remote loopback start 25 PORT[25]: The remote DTE loopback is success. SWITCH(bridge)#