7.1.9.2Default Alarm Severity

To configure a priority of alarm, use the following command.

Command

Mode

Description

 

 

 

snmp alarm-severity default

 

Configures the priority of alarm.

{critical major minor warning

Global

(default: minor)

intermediate}

 

 

 

 

 

 

7.1.9.3Alarm Severity Criterion

You can set an alarm severity criterion to make an alarm be shown only in case of se- lected severity or higher. For example, if an alarm severity criterion has been set to major, you will see only an alarm whose severity is major or critical.

To configure alarm-severity criteria in CLI, use the following command.

Command

Mode

Description

 

 

 

snmp alarm-severity criteria

 

Configures the severity criterion.

{critical major minor warning

Global

(default: warning)

intermediate}

 

 

 

 

 

 

i

!

The order of alarm severity is critical > major > minor > warning > intermediate.

The alarm severity option is valid only in ACI-E.