UMN:CLI

User Manual

 

SURPASS hiD 6615 S223/S323 R1.5

 

 

 

SWITCH(bridge)# show port 1

-------------------------------------------------------------------

NO

TYPE

PVID

STATUS

MODE

FLOWCTRL INSTALLED

 

 

(ADMIN/OPER)

 

 

-------------------------------------------------------------------

1: Ethernet

1

Up/Up Force/Half/100

SWITCH(bridge)# port speed 1 10

SWITCH(bridge)# show port 1

Off Y

-------------------------------------------------------------------

NO

TYPE

PVID

STATUS

MODE

FLOWCTRL INSTALLED

 

 

(ADMIN/OPER)

 

 

-------------------------------------------------------------------

1: Ethernet

1

Up/Up Force/Half/10

 

SWITCH(bridge)#

 

 

 

 

 

 

Off Y

5.2.4Duplex Mode

Only unidirectional communication is practicable on half duplex mode, and bidirectional communication is practicable on full duplex mode. By transmitting packet for two ways, Ethernet bandwidth is enlarged two times- 10Mbps to 20Mbps, 100Mbps to 200Mbps.

To set duplex mode, use the following command.

Command

Mode

Description

 

 

 

port duplex PORTS {full half}

Bridge

Sets full or half duplex mode of specified port, enter the

port number.

 

 

 

 

 

The following is an example of configuring duplex mode of port 1 as half mode and show- ing it.

SWITCH(bridge)# show port 1

-------------------------------------------------------------------

NO

TYPE

PVID

STATUS

MODE

FLOWCTRL INSTALLED

 

 

(ADMIN/OPER)

 

 

-------------------------------------------------------------------

 

 

 

 

 

 

 

 

1: Ethernet

1

Up/Up Force/Full/100

 

Off

Y

SWITCH(bridge)# port duplex

1 half

 

 

 

 

 

 

 

SWITCH(bridge)# show port 1

 

 

 

 

 

-------------------------------------------------------------------

NO

TYPE

PVID

STATUS

MODE

FLOWCTRL INSTALLED

(ADMIN/OPER)

-------------------------------------------------------------------

1: Ethernet

1

Up/Down Force/Half/100

Off

Y

SWITCH(bridge)#

 

 

 

 

 

 

 

 

 

 

 

 

5.2.5Flow Control

Ethernet ports on the switches use flow control to restrain the transmission of packets to the port for a period time. Typically, if the receive buffer becomes full, the port transmits a pause packet that tells remote ports to delay sending more packets for a specified period time. In addition, the Ethernet ports can receive and act upon pause packets from other devices.

76

A50010-Y3-C150-2-7619

Page 76
Image 76
Siemens S323, S223 user manual Duplex Mode, Flow Control, Command Mode Description Port duplex Ports full half, Half