4.1.7Auto Log-out

For security reasons of the hiD 6615 S223/S323, if no command is entered within the configured inactivity time, the user is automatically logged out of the system. Administra- tor can configure the inactivity timer.

To enable auto-logout function, use the following command.

Command

Mode

Description

 

 

 

 

 

Enables auto log-out.

exec-timeout<1-35791> [<0-59>]

Global

1-35791: time unit in minutes (by default 10 minutes)

 

0-59: time unit in seconds

 

 

 

 

 

exec-timeout 0

 

Disables auto log-out.

 

 

 

To display a configuration of auto-logout function, use the following command.

Command

Mode

Description

 

 

 

show exec-timeout

Enable

Shows a configuration of auto-logout function.

Global

 

 

 

 

 

The following is an example of configuring auto-logout function as 60 seconds and view- ing the configuration.

SWITCH(config)# exec-timeout60

SWITCH(config)# show exec-timeout

Log-out time : 60 seconds

SWITCH(config)#

4.1.8System Rebooting

4.1.8.1Manual System Rebooting

When installing or maintaining the system, some tasks require rebooting the system by various reasons. Then you can reboot the system with a selected system OS.

To restart the system manually, use the following command.

Command

Mode

Description

 

 

 

reload [os1 os2]

Enable

Restarts the system.

 

 

 

If you reboot the system without saving new configuration, new configuration will be de- leted. So, you have to save the configuration before rebooting. Not to make that mistake, hiD 6615 S223/S323 is supported to print the following message to ask if user really wants to reboot and save configuration.

If you want to continue to reboot, press <y> key, if you want to save new configuration, press <n> key.

SWITCH# reload

Do you want to save the system configuration? [y/n]]