UMN:CLI

User Manual

 

SURPASS hiD 6615 S223/S323 R1.5

 

 

 

To return ERP Test Packet Interval as Default, use the following command.

Command

Mode

Description

 

 

 

no erp test-packet-interval DO-

Bridge

Configures ERP test packet interval as default value

MAIN-ID

 

 

 

 

 

8.9.3.10Displaying ERP Configuration

To display a configuration for ERP, use the following command.

Command

Mode

Description

 

 

 

 

Enable

 

show erp {all DOMAIN-ID}

Global

Shows the information of ERP

 

Bridge

 

 

 

 

8.10Stacking

i

It is possible to manage several switches with one IP address by using stacking. If there’s a limitation for using IP addresses and there are too many switches which you must man- age, you can manage a number of switches with a IP address using this stacking function.

Switch stacking technology available in the industry today provides two main benefits to customers. The first benefit is the ability to manage a group of switches using a single IP address. The second benefit is the ability to interconnect two or more switches to create a distributed fabric, which behaves in the network as a unified system. The hiD 6615 S223/S323 provides the stacking technology’s benefits for the customer.

It is possible to configure stacking function for switches from 2 to 16.

The following is an example of the network where stacking is configured.

Switch

Switch A

Master Switch

Switch B

Slave Switch

Internet

SwitchSwitch

Switch C

Slave Switch

Fig. 8.39 Example of Stacking

270

A50010-Y3-C150-2-7619

Page 270
Image 270
Siemens S323, S223 user manual Stacking, Displaying ERP Configuration, Show erp all DOMAIN-ID