User Manual

UMN:CLI

SURPASS hiD 6615 S223/S323 R1.5

 

 

 

 

 

The following is an example of configuring syslog message to send all logs higher than notice to remote host 10.1.1.1 and configuring local1.info to transmit to console.

SWITCH(config)# syslog output notice remote 10.1.1.1

SWITCH(config)# syslog output priority local1 info console

SWITCH(config)# show syslog

System logger on running!

info

local

volatile

info

local

non-volatile

notice

remote 10.1.1.1

local1.info

console

SWITCH(config)#

 

 

7.5.2Facility Code

You can set a facility code of the generated syslog message. This code make a syslog message distinguished from others, so network administrator can handle various syslog messages efficiently.

To set a facility code, use the following command.

Command

Mode

Description

 

 

 

syslog local-code <0-7>

Global

Sets a facility code.

 

 

no syslog local-code

Deletes a specified facility code.

 

 

 

 

The following is an example of configuring priority of all syslog messages which is trans- mitted to remote host 10.1.1.1, as the facility code 0.

SWITCH(config)# syslog output err remote 10.1.1.1

SWITCH(config)# syslog local-code 0

SWITCH(config)# show syslog

System logger on running!

info

local volatile

info

local non-volatile

err

remote 10.1.1.1

local_code

0

SWITCH(config)#

 

7.5.3Syslog Bind Address

You can specify IP address to attach to the syslog message for its identity. To specify IP address for syslog identity, use the following command.

Command

Mode

Description

 

 

 

syslog bind-address A.B.C.D

Global

Specifies IP address for a syslog message identity.

 

 

no syslog bind-address

Deletes a specified binding IP address.

 

 

 

 