Siemens S323, S223 Authentication Password, To configure Vrrp Track, use the following command

Models: S323 S223

1 381
Download 381 pages 49.11 Kb
Page 232
Image 232

UMN:CLI

User Manual

 

SURPASS hiD 6615 S223/S323 R1.5

 

 

 

Internet

Virtual Router

Associate IP : 10.0.0.5/24

Master Router 1

Backup Router 1

Backup Router 2

IP : 10.0.0.3/24

IP : 10.0.0.2/24

IP : 10.0.0.1/24

1. Link Down

 

 

2. If the interface doesn’t recognize to

Default Gateway : 10.0.0.5/24

 

 

be Link down, it is supposed to be

 

 

inaccessible to Master Router.

 

 

Therefore the users on the interface

 

 

are not able to communicate.

 

 

Counter measure

3.If “Link down” happens, by giving low priority automatically to Master Router, Master Router will be changed at the same time with Link down.

Fig. 8.29 VRRP Track

To configure VRRP Track, use the following command.

Command

Mode

Description

 

 

 

track interface INTERFACE pri-

VRRP

Configures VRRP Track. The Priority becomes lower

ority <1-254>

as the configured value.

 

 

 

 

To release VRRP Track configuration, use the following command.

Command

Mode

Description

 

 

 

no track interface INTERFACE

VRRP

Disables VRRP Track configuration.

 

 

 

8.4.1.5Authentication Password

If anyone knows Group ID and Associated IP address, he can configure another device as a Virtual Router. To prevent this, user needs to configure a password, named authenti- cation password that can be used only in Virtual Router user configured.

232

A50010-Y3-C150-2-7619

Page 232
Image 232
Siemens S323, S223 user manual Authentication Password, To configure Vrrp Track, use the following command