UMN:CLI

User Manual

 

SURPASS hiD 6615 S223/S323 R1.5

 

 

 

4 System Connection and IP Address

4.1System Connection

After installing switch, the hiD 6615 S223/S323 is supposed to examine that each port is rightly connected to network and management PC. And then, user connects to system to configure and manage the hiD 6615 S223/S323. This section provides instructions how to change password for system connection, connect to system through telnet as the follow- ing order.

System Login

Password for Privileged EXEC Mode

Changing Login Password

Management for System Account

Limiting Number of User

Telnet Access

Auto Log-out

System Rebooting

4.1.1System Login

After installing the hiD 6615 S223/S323, finally make sure that each port is correctly con- nected to PC for network and management. And then, turn on the power and boot the system as follow.

Step 1

When you turn on the switch, booting will be automatically started and login prompt will be displayed.

SWITCH login:

Step 2

When you enter login ID at the login prompt, password prompt will be displayed. And en- ter password to open Privileged EXEC View mode. By default setting, login ID is config- ured as admin and it is possible to access without password.

SWITCH login: admin

Password:

SWITCH>

Step 3

In Privileged EXEC View mode, you can check only the configuration for the switch. To configure and manage the switch, you should begin Privileged EXEC Enable mode. The following is an example of beginning Privileged EXEC Enable mode.

SWITCH> enable

SWITCH#

40

A50010-Y3-C150-2-7619

Page 40
Image 40
Siemens S323, S223 user manual System Connection, System Login, Step