UMN:CLI

User Manual

 

SURPASS hiD 6615 S223/S323 R1.5

 

 

 

7.1.9.4Generic Alarm Severity

To configure generic alarm severity, use the following command.

Command

Mode

Description

 

 

 

snmp alarm-severity fan-fail {critical major

 

Configures the priority of fan-fail alarm

minor warning intermediate}

 

 

 

 

 

 

snmp alarm-severity cold-start {critical major

 

Configures the priority of cold-start

minor warning intermediate}

 

alarm

 

 

 

snmp alarm-severity broadcast-over {critical

 

Configures the priority of broadcast-

major minor warning intermediate}

 

over alarm

 

 

 

snmp alarm-severity cpu-load-over {critical

 

Configures the priority of cpu-load-over

major minor warning intermediate}

 

alarm

 

 

 

snmp alarm-severity dhcp-lease {critical ma-

 

Configures the priority of DHCP-lease

jor minor warning intermediate}

 

alarm

 

 

 

snmp alarm-severity dhcp-illegal {critical

 

Configures the priority of DHCP-illegal

major minor warning intermediate}

 

alarm

 

 

 

snmp alarm-severity fan-remove {critical

 

Configures the priority of fan-remove

major minor warning intermediate}

 

alarm

 

 

 

snmp alarm-severity ipconflict {critical major

 

Configures the priority of IP conflict

minor warning intermediate}

 

alarm

 

 

 

snmp alarm-severity memory-over {critical

 

Configures the priority of memory-over

major minor warning intermediate}

 

alarm

 

 

 

snmp alarm-severity mfgd-block {critical

 

Configures the priority of MFGD-block

major minor warning intermediate}

Global

alarm

 

 

snmp alarm-severity port-link-down {critical

Configures the priority of port-link-down

 

major minor warning intermediate}

 

alarm

 

 

 

snmp alarm-severity port-remove {critical

 

Configures the priority of port-remove

major minor warning intermediate}

 

alarm

 

 

 

snmp alarm-severity port-thread-over {critical

 

Configures the priority of port-thread-

major minor warning intermediate}

 

over alarm.

 

 

 

snmp alarm-severity power-fail {critical major

 

Configures the priority of power-fail

minor warning intermediate}

 

alarm

 

 

 

snmp alarm-severity power-remove {critical

 

Configures the priority of power-remove

major minor warning intermediate}

 

alarm

 

 

 

snmp alarm-severity rmon-alarm-rising {criti-

 

Configures the priority of RMON-alarm-

cal major minor warning intermediate}

 

rising alarm.

 

 

 

snmp alarm-severity rmon-alarm-falling {criti-

 

Configures the priority of RMON-alarm-

cal major minor warning intermediate}

 

falling alarm.

 

 

 

snmp alarm-severity system-restart {critical

 

Configures the priority of system-restart

major minor warning intermediate}

 

alarm.

 

 

 

snmp alarm-severity module-remove {critical

 

Configures the priority of module-

major minor warning intermediate}

 

remove alarm.

 

 

 

snmp alarm-severity temperature-high {critical

 

Configures the priority of temperature-

major minor warning intermediate}

 

high alarm.

 

 

 

114

A50010-Y3-C150-2-7619

Page 114
Image 114
Siemens S323, S223 user manual Generic Alarm Severity, 114 A50010-Y3-C150-2-7619