Siemens S223 Configuring Lacp, Packet Route, Activate Lacp function, using the following command

Models: S323 S223

1 381
Download 381 pages 49.11 Kb
Page 195
Image 195

User Manual

UMN:CLI

SURPASS hiD 6615 S223/S323 R1.5

 

 

 

 

 

Configuring LACP

Packet Route

Operating Mode of Member Port

Priority of Switch

Identifying Member Ports within LACP

BPDU Transmission Rate

Key value of Member Port

Priority

Displaying LACP Configuration

8.2.2.1Configuring LACP

Step 1

Activate LACP function, using the following command.

Command

Mode

Description

 

 

 

lacp aggregator

 

Enables LACP of designated Aggregator-number:

 

AGGREGATIONS: select aggregator ID that should be

AGGREGATIONS

 

 

enabled for LACP (valid value from 0 to 13).

 

Bridge

 

 

 

no lacp aggregator

Disables LACP for

designated Aggregator-number,

 

 

select the aggregator

ID that should be disabled for

AGGREGATIONS

 

 

LACP.

 

 

 

 

 

 

 

 

Step 2

Configure the physical port that is a member of aggregated port. In order to configure the member port, use the following command.

Command

Mode

Description

 

 

 

 

 

Configures physical port that is member port of aggre-

lacp port PORTS

 

gator; select the port number(s) that should be enabled

 

Bridge

for LACP.

 

 

 

no lacp port PORTS

 

Deletes member port of Aggregator, select the port

 

number(s) that should be disabled for LACP.

 

 

 

 

 

8.2.2.2Packet Route

When packets enter to logical port integrating several ports, if there’s no process to de- cide the packet route, it is not possible to use logical port effectively from focusing pack- ets on a particular member port.

If these packets enter to logical port aggregating several ports and there’s no way to de- cide packet route, the packets could be gathered on particular member port so that it is not possible to use logical port effectively.

Therefore the hiD 6615 S223/S323 is configured to decide the way of packet route in or- der to divide on member port effectively when packets are transmitted. It can be selected with Source IP address, destination IP address, source MAC address, destination MAC address and the user could get the information of packets to decided packet route.

A50010-Y3-C150-2-7619

195

Page 195
Image 195