Siemens S223, S323 user manual General Upgrade, A50010-Y3-C150-2-7619 373

Models: S323 S223

1 381
Download 381 pages 49.11 Kb
Page 373
Image 373

User Manual

UMN:CLI

SURPASS hiD 6615 S223/S323 R1.5

 

 

 

 

 

11 System Software Upgrade

For the system enhancement and stability, new system software may be released. Using this software, the hiD 6615 S223/323 can be upgraded without any hardware change. You can simply upgrade your system software with the provided upgrade functionality via the CLI.

11.1General Upgrade

The hiD 6615 S223/323 supports the dual system software functionality, which you can select applicable system software stored in the system according to various reasons such as the system compatibility or stability.

To upgrade the system software of the switch, use the following command.

Command

 

Mode

Description

 

 

 

 

copy {ftp tftp} os

download

 

Downloads the system software of the switch via FTP

 

or TFTP.

{os1 os2}

 

 

 

Enable

os1 os2: the area where the system software is stored

 

 

 

 

 

copy {ftp tftp} os upload {os1

 

Uploads the system software of the switch via FTP or

os2}

 

 

TFTP.

 

 

 

 

!

To upgrade the system software, FTP or TFTP server must be set up first. Using the copy

command, the system will download the new system software from the server.

!

To reflect the downloaded system software, the system must restart using the reload

command. For more information, see Section 4.1.8.

 

The following is an example of upgrading the system software stored in os1.

 

SWITCH# copy ftp os download os1

 

To exit : press Ctrl+D

 

--------------------------------------

 

IP address or name of remote host (FTP): 10.100.158.144

 

Download File Name : V5212G.3.18.x

 

User Name : admin

 

Password:

 

Hash mark printing on (1024 bytes/hash mark).

 

Downloading NOS ....

 

##############################################################################

 

##############################################################################

 

##############################################################################

 

##############################################################################

 

##############################################################################

 

##############################################################################

 