7.4.2.5Lower Bound of Threshold

If you need to occur alarm when object used for sample inquiry is less than lower bound of threshold, you should configure lower bound of threshold. To configure lower bound of threshold, use the following command.

Command

Mode

Description

 

 

 

falling-threshold NUMBER

RMON

Configures lower bound of threshold.

 

 

 

After configuring lower bound of threshold, configure to generate RMON event when ob- ject is less than configured threshold. Use the following command.

Command

Mode

Description

 

 

 

falling-event <1-65535>

RMON

Configures to generate RMON alarm when object is

less than configured threshold.

 

 

 

 

 

7.4.2.6Configuring Standard of the First Alarm

It is possible for users to configure the standard the first time alarm is occurred. The user can select the first point when object is more than threshold, or the first point when object is less than threshold, or the first point when object is more than threshold or less than threshold.

To configure the first RMON alarm to occur when object is less than lower bound of threshold first, use the following command.

Command

Mode

Description

 

 

 

startup-type falling

RMON

Configures the first RMON Alarm to occur when object

is less than lower bound of threshold first.

 

 

 

 

 

To configure the first alarm to occur when object is firstly more than upper bound of threshold, use the following command.

Command

Mode

Description

 

 

 

startup-type rising

RMON

Configures the first Alarm to occur when object is firstly

more than upper bound of threshold.

 

 

 

 

 

To configure the first alarm to occur when object is firstly more than threshold or less than threshold, use the following command.

Command

Mode

Description

 

 

 

startup-type rising-and-falling

RMON

Configures the first Alarm to occur when object is firstly

more than threshold or less than threshold.

 

 

 

 

 

7.4.2.7Interval of Sample Inquiry

The interval of sample inquiry means time interval to compare selected sample data with upper bound of threshold or lower bound of threshold in terns of seconds.

A50010-Y3-C150-2-7619

131