Siemens S223 Source Port of Statistical Data, Subject of Rmon History, Number of Sample Data

Models: S323 S223

1 381
Download 381 pages 49.11 Kb
Page 127
Image 127

User Manual

UMN:CLI

SURPASS hiD 6615 S223/S323 R1.5

 

 

 

 

 

want to list available commands.

The following is an example of listing available commands on RMON Configuration mode.

SWITCH(config-rmonhistory[5])# ?

 

RMON history configuration commands:

 

active

Activate the history

 

data-source

Set data source port

 

do

To run exec commands

in config mode

exit

End current mode and

down to previous mode

help

Description of the interactive help system

interval

Define the time interval for the history

owner

Assign the owner who

define and is using the history

 

resources

 

requested-buckets

Define the bucket count for the interval

show

Show running system information

SWITCH(config-rmonhistory[5])#

 

7.4.1.1Source Port of Statistical Data

To specify a source port of statistical data, use the following command.

Command

Mode

Description

 

 

 

data-source NAME

RMON

Specifies a data object ID.

NAME: enters a data object ID. (ex. ifindex.n1/port1)

 

 

 

 

 

7.4.1.2Subject of RMON History

To identify subject using RMON history, use the following command.

Command

Mode

Description

 

 

 

owner NAME

RMON

Identifies subject using related data, enter the name

(max. 32 characters).

 

 

 

 

 

7.4.1.3Number of Sample Data

To configure the number of sample data of RMON history, use the following command.

Command

Mode

Description

 

 

 

 

 

Defines a bucket count for the interval, enter the num-

requested-buckets <1-65535>

RMON

ber of buckets.

 

 

1-65535: bucket number (default: 50)

 

 

 

7.4.1.4Interval of Sample Inquiry

To configure the interval of sample inquiry in terms of second, use the following command.

Command

Mode

Description

 

 

 

interval <1-3600>

RMON

Defines the time interval for the history (in seconds),

enter the value. (default: 1800)

 

 

 

 

 