Cornelius QUANTUM SERIES Installation Specifications, Water Supply, Electrical, Space

Models: QUANTUM SERIES

1 37
Download 37 pages 15.63 Kb
Page 5
Image 5
INSTALLATION

Quantum Series Installation and Service Manual

INSTALLATION

SPECIFICATIONS

WATER SUPPLY

The Quantum Juice Dispensing machine is designed to dispense juice at a high flow rate. It is very important that the incoming water line is dedicated for the unit, or at least does not have other machines connected which could cause a water surge; i.e., a dishwashing machine.

NOTE: For increased cooling capacity the unit should be connected to a remote recirculating cooling unit. If the location is equipped with a dedicated beverage wa- ter supply system the juice dispenser should be connected to it.

NOTE: The water supply should be consistent with proper water quality standard (neutral ph of 7.0 to 8.0), and should not be connected to a water softener. The wa- ter cooling coil is Copper, and may be affected by poor water conditions (i.e. severe corrosion and pitting).

Water connections shall be sized, installed, and maintained according to Federal, State, and Local Laws.

ELECTRICAL

A minimum of 15 amps electrical service is needed for 120V power supply or 10 amps for 220V supply.

SPACE

The minimum clearance is: 4” (10.16cm) in back and 12” (30.48cm) on top and open to the front if sides are blocked off. If the sides are open then only 2” (5.08cm) is required in the back. Space between the bottom of the unit and the counter cannot be obstructed.

NOTE: Condenser air is drawn from the bottom and discharged out the back. Fail- ure to maintain clearance space will reduce capacity of the unit and cause prema- ture compressor failure.

CONNECTING WATER SUPPLY

1.Secure 3/8” (0.95cm) flexible hose to the unit water inlet. Make sure that the seal washer is used (hose and seal washer are included with the installation kit).

2.When securing flare nut use backup wrench on male side of the fitting (unit side) to prevent twisting of the copper tube inside the unit and/or possible damage to the water strainer/sole- noid. A water shut off outside the unit is recommended.

FILLING UNIT WITH WATER

To properly prime the unit with water, without air pockets in the system, push the dispensing switches simultaneously for a few seconds each. Repeat above until a steady flow of water is observed.

NOTE: Water splashing may occur during the purge cycle.

- 3 -

720901120

Page 5
Image 5
Cornelius QUANTUM SERIES service manual Installation Specifications, Electrical, Space, Connecting Water Supply