Cornelius QUANTUM SERIES Concentrate warm, water cold con’t Brix Problem Pump Inoperative

Models: QUANTUM SERIES

1 37
Download 37 pages 15.63 Kb
Page 18
Image 18
Concentrate warm, water cold (con’t)

Quantum Series Installation and Service Manual

Concentrate warm, water cold (con’t)

Brix Problem

Pump Inoperative

Loss of refrigerant charge due to leak in system

Water supply pressure too low, less than 20 psi (1.4 bar) flowing or water pressure fluctuates sharply

Water flow control binding or spring is defective

Improperly thawed concen- trate. Brix changes as the concentrate temper- ature changes (concen- trate becomes thinner as temperature rises)

Check that the rollers on the pump are spinning freely with no tube in place

Pump motor defective

No power to transformer or no 28VAC output from transformer

Defective voltage regulator board (VRB) located inside front electrical box

Defective portion control board

Repair leak and recharge system

Correct water supply problem to ensure a constant 40 psi (3 bar) flowing to the dispenser

Clean and/or replace parts as nec- essary

Concentrate should 34oF -40 oF (1.1 oC –4.5 oC) prior to loading

If they are sticky or locked up see platform removal and cleaning procedure.

28VDC should be present at pump motor during dispense. If volt- age is present and motor does not start, replace pump motor

Confirm transformer has line volt- age present on primary side. If no 28VAC output from the sec- ondary replace transformer

Measure across the blue and black wire located in the upper left corner of the board. There should be 28VDC present when the dispense button is pressed. Replace VRB if necessary

Disconnect wire harness from rear of portion control, close door switch and short the orange and black wires together on the harness. If unit dispenses por- tion control board is defective. If it does not dispense the voltage regulator board is defective.

720901120

- 16 -

Page 18
Image 18
Cornelius QUANTUM SERIES Concentrate warm, water cold con’t Brix Problem Pump Inoperative, Pump motor defective, 720901120