UNIT SPECIFICATIONS

Quantum Series Installation and Service Manual

UNIT SPECIFICATIONS

Clearance Recommended: 12” (30.48 cm) on top and 4” (10.16 cm) required in back for air circula- tion if sides are blocked off. If sides are open only 2” (5.08) are required in back. Space between bottom of unit and counter cannot be obstructed in foot print area.

Electrical Connection: 6ft. long (1.83m) power cord with 3-prong plug attached to dispenser. Export models have line cord less plug.

Power Supply: 15 amps at 120 volts or 10 amps at 220 volts.

Water Connection: 3/8” (0.95 cm) SAE male flare fitting on dispenser.

Water Supply Requirements: 80 psi (5.5 bar) maximum static pressure. 20 psi (1.4 bar) minimum dynamic pressure; i.e., flowing pressure measured at dispenser water inlet with 3.0 ounces (88.7ml) per second water flow.