FLUSHING AND SANITIZING ON START UP

Quantum Series Installation and Service Manual

FLUSHING AND SANITIZING ON START UP

Follow standard sanitizing and flushing procedure.

PROGRAMMING PORTION CONTROL (OPTIONAL)

The portion control supplied with your orange juice dispenser has been programmed to pour 7, 12, and 16 ounce drinks. The “XL” size has also been programmed to pour 16 ounces. Should pour size adjustments be required, please follow the instructions below:

1.Simultaneously, press and hold “S” (small) and “XL” (extra large) push button switches on the Portion Control Module until the led “REFILL” light in the corner of the module starts blinking. Release the switches. The blinking led indicates the programming mode is active.

2.Place the cup under the white mixing valve nozzle and push the selected size button (small, medium, large, or extra large). Hold the button in until the cup fills to the desired portion, then release the button repeat the above procedure for the remaining sizes.

3.After programming all the drink sizes, press and release the “cancel/pour” switch to return the Portion Control to the operational mode. The blinking led light will go out.

If at a future date, it is decided to change the portion size of the drinks, the individual sizes can be adjusted by the above procedure. It is not necessary to reprogram every size.

The portion control has a full memory retention in case of a power failure.

CANCEL/POUR BUTTON

Push and release the cancel/pour button to stop the valve from dispensing.