Quantum Series Installation and Service Manual
Machine continues to dispense after dis- pense button is released or dis- penses without operator input
Sold Out light illumi- nates when concen- trate no longer passes through the pump.
Portion control pad stuck in on position
Relay on voltage regulator board (VRB) stuck on.
The concentrate is improp- erly thawed. The tem- perature is not maintained between 34×F -
High Brix readings result in
apoor, pulsating/splash- ing dispense, erratic pump amp draw, and consequently erratic
Disconnect the wire harness from the rear of the portion control and close the door. If unit does not dispense on its own the por- tion control is bad (stuck on)
Disconnect the
Assure proper thawing procedures have been followed per the Minute Maid company instruc- tions.
Check that McDonald’s
Check the dispenser cabinet tem- perature is at 34×F - 40×F(1.1- 4.5×C).
Check drink brix in procedure described on equipment P.M. card using the hydrometer pro- vided.
Check the drink flow rate under normal operating conditions. The dispenser should pour a drink at a flow rate of approxi- mately 1.5 oz. Per second or greater. If the flow rate is less, a check described in the Sold Out section should be completed.
- 17 - | 720901120 |