Cornelius QUANTUM SERIES Portion control pad stuck in on position, High Brix readings result in

Models: QUANTUM SERIES

1 37
Download 37 pages 15.63 Kb
Page 19
Image 19
Portion control pad stuck in on position

Quantum Series Installation and Service Manual

Machine continues to dispense after dis- pense button is released or dis- penses without operator input

Sold Out light illumi- nates when concen- trate no longer passes through the pump.

Portion control pad stuck in on position

Relay on voltage regulator board (VRB) stuck on.

The concentrate is improp- erly thawed. The tem- perature is not maintained between 34×F - 40×F(1.1-4.5×C)

High Brix readings result in

apoor, pulsating/splash- ing dispense, erratic pump amp draw, and consequently erratic sold-out indications.

Disconnect the wire harness from the rear of the portion control and close the door. If unit does not dispense on its own the por- tion control is bad (stuck on)

Disconnect the 4-wire harness from the lower right corner of the VRB. If the unit continues to dispense on its own the VRB is defective (relay stuck on)

Assure proper thawing procedures have been followed per the Minute Maid company instruc- tions.

Check that McDonald’s walk-in cooler temperature is on the proper set point.

Check the dispenser cabinet tem- perature is at 34×F - 40×F(1.1- 4.5×C).

Check drink brix in procedure described on equipment P.M. card using the hydrometer pro- vided.

Check the drink flow rate under normal operating conditions. The dispenser should pour a drink at a flow rate of approxi- mately 1.5 oz. Per second or greater. If the flow rate is less, a check described in the Sold Out section should be completed.