Adjust Switch.

Quantum Series Installation and Service Manual

Sold Out light illumi- nates when concen- trate no longer passes through the pump.(con’t)

Sold Out light fails to reset itself after door is opened and closed (Sold Out light stays illumi- nated)

Improper loading proce- dures will usually result in low brix conditions and thus erratic sold out indications.

Tube has been stretched through pump when it was loaded. Pouch may not be seated correctly.

Check that the rollers on the pump are spinning freely with no tube in place.

Check the operation of the reset switch located at the bottom left hand side of the door.

Check that the pouch of juice is properly loaded in the pouch holder. Tube fitting should be located at the bottom of the pouch holder and the tube should be approximately cen- tered in the bottom portion of the opening of the holder.

Check that the tube is correctly loaded in the pump and the pump is fully locked (top and bottom slide pins should be fully engaged into the pump body).

Adjust pouch. If pouch is loaded correctly there should be ample tube to reach the mixing cham- bers without stretching the tube.

If the rollers are sticky or locked up see the platform removal and cleaning procedure.

Adjust Switch.

720901120